Con-Tec Solutions

EV & Solar Service

Battery Storage

Commercial battery energy storage system (BESS) installation — DC-coupled and AC-coupled configurations, BMS integration, grid protection, DNO application and full BS 7671 commissioning for commercial and industrial premises.

What a commercial battery storage project actually has to solve

01

Peak demand charges that outweigh energy cost

Demand charges can represent a significant proportion of commercial electricity costs where peak consumption triggers higher tariff bands or network capacity charges. Battery storage systems can shift demand away from peak tariff periods — we model the demand profile against the available storage capacity to verify the financial case before specifying any equipment.

02

Solar generation that isn't being used on site

Solar PV systems without storage export excess generation at lower export tariff rates. DC-coupled battery storage captures this generation and makes it available for on-site consumption at peak demand times — we design the combined solar and storage system as a single coordinated package.

03

Grid protection requirements for larger storage systems

Battery storage systems above certain capacity thresholds require G99 grid protection and DNO approval. We manage the application and protection relay commissioning as part of the project scope — so this doesn't become a programme-blocking afterthought.

04

BMS integration with existing energy management systems

Larger commercial sites operate energy management and building management systems that need to coordinate with the battery storage controller. We design and commission the communications interface as part of the electrical scope — so the storage system integrates with your existing monitoring and control infrastructure.

NHS
Eric Wright FM
Manchester Central
Beghelli Lighting
Thorn
CAFT - Children's Adventure Farm Trust
NHS
Eric Wright FM
Manchester Central
Beghelli Lighting
Thorn
CAFT - Children's Adventure Farm Trust

Technical detail

Standards & compliance

  • BS 7671 — DC and AC circuit requirements for BESS
  • Engineering Recommendation G99 / G98 — grid connection
  • IET Code of Practice for Energy Storage Systems
  • BS EN 62619 — safety requirements for BESS
  • DNO technical requirement compliance

System configurations

  • DC-coupled storage (integrated with solar inverter)
  • AC-coupled storage (standalone inverter/charger)
  • Front-of-meter and behind-the-meter configurations
  • Three-phase balancing and neutral management
  • Islanding and backup power capability

Electrical installation

  • DC isolation, fusing and protection
  • AC connection and protection relay installation
  • Grid protection relay settings and commissioning
  • BMS communications wiring and interface
  • Cable management for DC and AC circuits

Documentation

  • DNO G99/G98 application and approval management
  • As-installed single-line diagram
  • BS 7671 test certificates
  • Protection relay settings record
  • O&M documentation and handover pack
Con-Tec Solutions — battery storage installation

The Numbers

Grid connection managed

G99

G99 application, protection relay commissioning and DNO approval managed as part of the project scope — not a post-installation afterthought.

Coupling configurations

DC+AC

We design and install both DC-coupled (solar-integrated) and AC-coupled (standalone) battery storage configurations to suit the specific site and load profile.

Monitored from commissioning

100%

BMS and energy management system integration commissioned at handover — with a generation and consumption baseline from day one.

Why specify Con-Tec

Storage Projects That Deliver on the Business Case

01

Demand profile modelling before specification

We model your demand profile against the proposed storage capacity before recommending any equipment — so the financial case is based on your actual load pattern, not a generic example.

02

Combined solar and storage design

We design solar PV and battery storage as a single coordinated system — enabling DC coupling, combined export management and smart charging prioritisation.

03

G99 grid protection as standard

Grid protection relay commissioning and DNO G99 approval are included in our standard scope for systems above the G98 threshold — not an extra.

04

BMS integration capability

We design and commission the communications interface between the battery management system and your existing BMS or energy management platform — so the storage system integrates from day one.

01

Demand Survey & Modelling

Demand profile review, peak consumption analysis and storage capacity modelling before any equipment is specified.

02

Design & DNO Application

System design, protection relay specification and G99/G98 application submitted to the DNO at the start of the design stage.

03

Installation

BESS enclosure, DC isolation, AC connection, protection relay and BMS communications installed to BS 7671 by NICEIC-approved engineers.

04

Commission & Handover

Protection relay commissioning, BMS integration verification, full BS 7671 testing and documentation package at handover.

NICEIC Approved Contractor
Constructionline Gold Member
International Powered Access Fedaration
Prefabricated Access Suppliers & Manufacturers Association

1 / 4

What our clients say

“Just a note to say that John and his team from Con-Tec Solutions have produced another outstanding performance on the refit of lighting in the atrium at BCW. Work carried out was done at an extremely high standard. All relevant risk assessments and method statements brought to site and adhered to. These guys really do set the standards that we should be expecting from all our contractors.”

Grant Metcalf, Eric Wright Facilities Management

Get a Quote

Ready to Start a Project?

Our team is on hand to discuss your commercial or industrial electrical requirements. Share your project details with us, and we’ll be in touch to discuss the scope, programme and a tailored, cost-effective solution.